Noritz Water heater 91 Error Code

What the 91 code means

Incorrect gas type: the unit is being supplied with, or is set up for, the wrong gas type.

Likely causes

  1. Unit supplied natural gas when set up for propane, or vice versa
  2. Manifold gas pressures incorrectly set after a gas conversion
  3. Dirty fan, burner and heat exchanger fins compounding poor combustion

How to fix it — step by step

  1. Identify the mismatch first: read the unit's rating/conversion data and confirm which gas the unit is set up for, then confirm which gas is actually supplied (natural gas or propane). Code 91 means those two do not agree, or the conversion was not completed correctly. Do not run the unit on the wrong gas while this is unresolved.
  2. The checkpoints for 91, for both new and existing installs, are: verify the unit is provided the correct gas type, and verify the installation follows the installation manual for that gas type. A unit that shows 91 right after a conversion or a move is telling you the conversion state — not a failed part — is the first suspect.
  3. Have a service representative verify the manifold gas pressures are correctly set (this step belongs to the service rep; it is a manometer test at the manifold, and pressures outside the specification after a conversion confirm the conversion/setup is wrong and are corrected there).
  4. The service representative also cleans the fan, burner and heat exchanger fins if there is dust, dirt or lint build-up (a listed step for existing installations), since fouled combustion parts compound poor combustion once the gas type is corrected.
  5. Verify by test-firing the unit after the gas type / pressures are corrected: normal ignition and a sustained hot-water run with 91 staying clear is the pass; 91 returning means the supplied gas and the unit's setup still do not match and the unit stays off until they do.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 91 code

No specific replacement part is documented for this fault. If the checks above do not clear it, your water heater likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.