Noritz Water heater NCC199CDV 41 Error Code

What the 41 code means

Flow not detected at a secondary unit: in a multi-unit installation of the commercial NCC199CDV, the second or subsequent unit cannot operate because it cannot detect flow rate. This code only applies to the NCC199CDV in a multi-unit installation.

Likely causes

  1. Secondary unit cannot detect flow rate through the system
  2. Multi-unit plumbing/flow configuration preventing flow at the secondary unit

How to fix it — step by step

  1. Verify water is actually flowing through the second/subsequent unit - check its inlet/outlet valves are open.
  2. Check the multi-unit installation piping and system controller setup so flow reaches the secondary unit when it is called.
  3. Have Noritz technical support or the installer correct the multi-unit configuration if flow is present but still not detected.
  4. Verify the fix: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 41 should stay clear through the whole draw. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 41 code

No specific replacement part is documented for this fault. If the checks above do not clear it, your water heater likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Noritz Water heater NCC199CDV error codes

See all Noritz NCC199CDV codes & guides →