Noritz Water heater NRCR 63 Error Code
What the 63 code means
Recirculation abnormality: the unit is trying to run the recirculation pump but is not detecting any flow in the recirculation loop.
Likely causes
- Return line filter clogged or water shut-offs closed (new and older installs)
- Air in the domestic hot water and return lines (dedicated mode)
- Crossover connector not connected or crossover valve filter clogged (crossover mode)
- Failed recirculation pump, recirculation flow sensor or circuit board
How to fix it — step by step
- On new installs: check the return line filter and that the water shut-offs are open; purge air from the domestic hot and return lines in dedicated mode; check the crossover connector is connected together and clean the crossover valve filter in crossover mode.
- On older installs: check the return line filter and water shut-offs.
- For error 63 (recirculation abnormality), the pinpoint order is: verify the recirculation pump is connected to the wire harness, and that the harness is properly connected to the circuit board. Where that is: the pump is built into the unit — power OFF, front cover off, and follow the pump's wire harness inside the cabinet to its connector on the circuit board.
- If a harness connector is unplugged or loose, reconnecting it is the repair — restart and confirm recirculation runs with no error 63.
- If the pump and harness are properly connected and error 63 persists, the fault is the recirculation pump or the circuit board — those are the two replaceable endpoints, in that order.
- Verify the fix: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 63 should stay clear through the whole draw. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Recirculation pump.
Shop the Recirculation pump at Amazon
Also tied to this fault: Recirculation flow sensor - Shop at Amazon; Circuit board - Shop at Amazon
Parts that commonly fix the 63 code
- Recirculation pumpShop at Amazon
- Recirculation flow sensorShop at Amazon
- Circuit board$100–$300Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.