Noritz Water heater NCC199 / NRC111 20 Error Code
What the 20 code means
High limit switch triggered: the water high limit switch opened on excessive temperature and stopped the burner.
Likely causes
- Scale deposits in the heat exchanger causing overheating
- Clogged cold water inlet filter restricting flow
- Failed or faulty high limit switch
How to fix it — step by step
- Disconnect power — the Noritz list states power must be disconnected to reset this error code.
- Clean the cold water inlet filter: it is the small screen in the cold inlet fitting at the bottom of the unit (water off, the filter cap unscrewed, screen rinsed) — and clean any recirculation return filter the same way. A clogged filter starves flow and overheats the exchanger, which is what this switch caught.
- Descale/flush the heat exchanger with descaling equipment through the isolation valves — scale is the other documented cause of the overheat.
- The high limit switch is mounted on the heat exchanger outlet at the top of the exchanger, reached with the front cover off: check its operation — it should reset/close once the unit has cooled. A switch that stays open on a cool exchanger, or that trips again on a clean, descaled unit at normal flow, has failed and is replaced (connectors off, switch unclipped from its mount, new switch fitted). → Shop the high limit switch at Amazon
- Restore power and prove a full high-demand cycle with no code 20.
- If you hand it over, tell the technician: code 20 — high limit switch triggered — and whether the inlet filter was clogged and when the unit was last descaled.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 20 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the High limit switch.
Shop the High limit switch at Amazon
Also tied to this fault: Descaling solution - Shop at Amazon
Parts that commonly fix the 20 code
- High limit switchShop at Amazon
- Descaling solutionShop at Amazon
- Tools for this job, if you need them$10–$40
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.