Weil-McLain Boiler Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 20 codes covered.
Finding your model number: it is on the rating plate on the boiler jacket, often behind the front panel.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
ECO Tec (plain-language fault displays)
Faults show as plain-language messages on the control display (IGNITION 1 FAULT, LOW WTR CUTOFF OPEN) rather than numbers; the manual's fault table states each one's reset behaviour - auto reset, timed retry, or manual reset.
| Code | What it means | Check first | |
|---|---|---|---|
| Air Pressure Switch Open | The air pressure switch connection is open, so the control cannot prove that combustion air is moving and… | Blocked or restricted vent or intake piping | › |
| Blower Fault 1 | The blower does not reach zero RPM within four minutes when the boiler is in Standby or Prepump mode. A… | Loose or disconnected low voltage wires to the blower motor | › |
| Blower Fault 2 | The blower is unable to reach the required pre-purge speed or the ignition speed, or it failed to complete… | Loose or damaged wires on the high voltage blower motor harness | › |
| Blower Fault 3 | The blower ran outside its minimum or maximum speed range for ten seconds. The control drives the blower to a… | Loose or damaged wires on the high voltage or low voltage blower motor harnesses | › |
| Closure Switch fault | The proof of closure connections on J18A pins 2 and 3 are open, so a device that must prove closed before… | Factory jumper loose or on the wrong pins at J22 or the closure connection | › |
| Configuration fault | The configuration data stored in the control safety micro does not match the data in the control application… | Control settings changed or corrupted so the two stored copies disagree | › |
| Control fault | The microcontrollers on the main control board have reported a RAM or ROM error, so the control no longer… | RAM error in the main control board | › |
| DHW Outlet > Boiler Out | On Combi models only, the DHW outlet sensor reads more than 10 degrees F above the boiler outlet sensor and… | Insufficient water flow delivered by the installed circulators | › |
| FALSE FLAME | The control is detecting a flame signal when there should be no flame. Either flame is genuinely still… | Gas valve not closing, so flame continues after shutdown | › |
| FLAME LOSS FAULT | The boiler went through five ignition attempts and the flame value dropped below proof of ignition during the… | Restricted or blocked flue pipe or intake pipe | › |
| FLUE TEMP TOO HIGH | The flue temperature sensor has passed 210 degrees F, which is the warning level, or 220 degrees F, which is… | Buildup or abnormal wear in the heat exchanger, combustion chamber or flue ways | › |
| GAS RELAY FAULT | The control has detected a problem with the gas valve output circuit, shown as GAS RELAY FAULT 1 through 4… | Loose or damaged wiring between the gas valve and the control | › |
| HIGH TEMP LIMIT | The boiler temperature sensor has reached the High Temp Limit setting, so the control has shut the burner… | High limit setting less than 10 degrees F above the maximum target temperature plus the | › |
| IGNITION 1 FAULT | The boiler went through five ignition attempts and never detected flame at all, or the flame sense value… | Blocked condensate trap letting condensate build up in the heat exchanger | › |
| IGNITION 2 FAULT | The boiler went through five ignition attempts and lit, but the flame never reached the running flame… | Fouled or worn igniter or ignition electrode | › |
| LIMIT OPEN | A manual reset or automatic reset external limit device wired to the control has opened, breaking the safety… | External safety limit device opened on a real condition | › |
| LOW WTR CUTOFF OPEN | The internal low water cutoff contacts are open, so the control is treating the boiler as low on water and… | Low water condition in the system | › |
| RETURN > SUPPLY | The return water temperature is higher than the supply temperature by 10 degrees F or more, and the burner… | Boiler circulator moving water in the wrong direction | › |
| Supply 60F > Return | One of the boiler out temperatures is more than 60 degrees F above the boiler in temperature while the burner… | Inadequate water flow through the boiler | › |
| TEMP RISE TOO QUICKLY | The supply water temperature inside the heat exchanger rose faster than 10 degrees F per second during the… | Piping installed incorrectly for the boiler | › |
Common questions
What does IGNITION 1 FAULT mean on a Weil-McLain ECO Tec?
The boiler made 5 ignition attempts and never proved flame - the flame sense never reached its minimum threshold. The manual's checks run from the condensate trap and ignition cable (1,000 ohms +/-50) to the igniter gap (4.5 mm) and gas pressure.
What does LOW WTR CUTOFF OPEN mean?
The low water cutoff has opened and the fault needs a manual reset: check the boiler's water level first, then the LWCO probe and its status in Diagnostics - Inputs, before suspecting the control.
Once you know the part you need, browse Weil-McLain Boiler replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.