Weil-McLain Boiler ECO Tec 80/110/150/199 Closure Switch fault
What this problem usually means
The proof of closure connections on J18A pins 2 and 3 are open, so a device that must prove closed before firing, such as a flow switch or a combustion air damper, has not proven. Which device applies depends on what is fitted: a factory jumper, a flow switch, or a damper. The control cannot start until that proof closes.
Likely causes
- Factory jumper loose or on the wrong pins at J22 or the closure connection
- Flow switch not closing because the correct pump is not on
- Flow switch wiring fault
- Damper not opening or no voltage to the damper
How to fix it — step by step
- Record the display text and note which closure device is fitted to this installation.
- Safety: switch the service switch off before checking jumpers, switch wiring or damper wiring.
- Locate the closure connections at J18A pins 2 and 3 on the control and trace the harness to the fitted device, and check the factory jumper on the J22 connection.
- Test: with no device fitted, confirm the jumper is on the correct pins with a secure connection. With a flow switch fitted, confirm the correct pump runs and the switch closes with flow. With a damper fitted, check for voltage at the damper and confirm it physically opens.
- End at the pinpointed cause: reseat or correct the jumper, repair the flow switch wiring or replace a switch that will not close with flow, or repair the damper power or the damper itself.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Flow switch.
Parts that commonly fix it
- Flow switchShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.