Weil-McLain Boiler ECO Tec 80/110/150/199 GAS RELAY FAULT Error Code
What the GAS RELAY FAULT code means
The control has detected a problem with the gas valve output circuit, shown as GAS RELAY FAULT 1 through 4 depending on which check failed. The control retries automatically, goes to lockout if the retry fails, and retries again one hour after lockout. A lockout that is still present at that retry needs a manual reset.
Likely causes
- Loose or damaged wiring between the gas valve and the control
- Faulty gas valve output circuit in the control
- Defective gas valve
How to fix it — step by step
- Record the exact fault number shown after GAS RELAY FAULT and whether it clears on the automatic retry.
- Safety: switch the service switch off and close the gas shutoff before touching gas valve wiring.
- Locate the gas valve inside the boiler and follow its harness back to the control, checking every connection for looseness, pin damage or chafing.
- Test: restore power and let the control retry. A fault that follows a reseated, undamaged harness is no longer a connection problem, which leaves the valve output circuit or the valve itself.
- End at the pinpointed cause: repair the harness connections if they were at fault. If the fault returns on a sound harness, the control or the gas valve is the failed part and this becomes technician work.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Gas valve.
Also tied to this fault: Control board - Shop at Amazon
Parts that commonly fix the GAS RELAY FAULT code
- Gas valve$100–$355Shop at Amazon
- Control boardShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.