Weil-McLain Boiler ECO Tec 80/110/150/199 TEMP RISE TOO QUICKLY Error Code

What the TEMP RISE TOO QUICKLY code means

The supply water temperature inside the heat exchanger rose faster than 10 degrees F per second during the first two minutes the burner was on. That rate of rise means heat is being made faster than water is carrying it away, which points to low or no flow through the boiler rather than a burner fault. The control resets automatically after a one minute delay, or sooner with a manual reset on the display.

Likely causes

  1. Piping installed incorrectly for the boiler
  2. Circulator wrong size or wrong speed for the boiler and system
  3. A temperature sensor fault making the control misread the rise

How to fix it — step by step

  1. Record the exact display text and whether the burner had just lit when it appeared.
  2. Safety: switch the boiler service switch off before opening panels or touching wiring.
  3. Locate the boiler circulator on the boiler loop piping and confirm its direction arrow points in the correct flow direction for the piping layout.
  4. Test: restore power and call for heat. A circulator that hums but does not move water, or a loop that stays cold while the boiler outlet climbs fast, confirms the flow problem the code is reporting.
  5. End at the fix: correct the piping or replace or re-speed the circulator so flow matches the boiler size and system requirements, then reset on the display and watch a full firing cycle.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the TEMP RISE TOO QUICKLY code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Weil-McLain Boiler ECO Tec 80/110/150/199 error codes

See all Weil-McLain ECO Tec 80/110/150/199 codes & guides →