What this problem usually means
The blower does not reach zero RPM within four minutes when the boiler is in Standby or Prepump mode. A blower that will not prove it has stopped cannot be trusted for the next start sequence, so the control faults it. The fault clears automatically after one hour.
Likely causes
- Loose or disconnected low voltage wires to the blower motor
- Damaged blower speed signal harness
- Failed blower motor
How to fix it — step by step
- Record the display text and note whether the blower is audibly still turning after a call for heat ends.
- Safety: switch the service switch off and verify power is off before handling blower wiring. Wait for the blower wheel to stop before reaching near it.
- Locate the blower on top of the heat exchanger assembly and follow its low voltage harness back to the control.
- Test: inspect the low voltage blower motor harness for loose or disconnected wires and reseat each connection. A blower that still will not report zero RPM on a sound harness has a failed speed signal or motor.
- End at the pinpointed cause: repair the harness connections if they were loose. If the fault returns, the blower is the failed part and is replaced by a technician.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Blower.
Parts that commonly fix it
- BlowerShop at Amazon
- Tools for this job, if you need them$15–$65
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.