Weil-McLain Boiler ECO Tec 80/110/150/199 LIMIT OPEN Error Code
What the LIMIT OPEN code means
A manual reset or automatic reset external limit device wired to the control has opened, breaking the safety circuit. An automatic limit resets the boiler about two and a half minutes after the device closes again, while a manual limit fault must be cleared by choosing Manual Reset on the display. The open device, or a missing jumper where no device is fitted, is the fault.
Likely causes
- External safety limit device opened on a real condition
- Loose wiring connections at the limit device
- Missing jumper across the MAN LIMIT terminals when no manual limit is used
- Missing jumper across the AUTO LIMIT terminals when no automatic limit is used
How to fix it — step by step
- Record the display text and note any external limit devices fitted to the system.
- Safety: switch the service switch off before opening the control cover or testing the limit circuit. Do not jumper out a limit to run the boiler.
- Locate the limit connections inside the control compartment and remove the control cover to inspect the connectors and the MAN LIMIT and AUTO LIMIT terminals.
- Test: check each external limit for continuity. A device that stays open at normal temperature has failed or is reporting a real over-temperature or low water event upstream, and a circuit that is open only at a missing jumper explains itself.
- End at the fix: correct the cause that opened the limit, repair loose connections, and install the jumper across any limit terminal pair that has no device fitted. Reset a manual limit fault from the display.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the External limit device.
Parts that commonly fix the LIMIT OPEN code
- External limit deviceShop at Amazon
- Tools for this job, if you need them$15–$65
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.