Weil-McLain Boiler ECO Tec 80/110/150/199 HIGH TEMP LIMIT Error Code
What the HIGH TEMP LIMIT code means
The boiler temperature sensor has reached the High Temp Limit setting, so the control has shut the burner down on high temperature. This usually means heat was not moving away from the boiler, because valves were closed, a circulator was not running, or the limit setting sits too close to the target temperature. Reset is done from the manual reset screen on the display.
Likely causes
- High limit setting less than 10 degrees F above the maximum target temperature plus the off differential
- Isolation valves closed
- Circulator not programmed into the control or not running
- Piping installed incorrectly
- Incorrect combustion making the burner run too hot
How to fix it — step by step
- Record the display text, the boiler temperature and the High Temp Limit setting from the control.
- Safety: let the boiler cool before working on it, and switch the service switch off before opening panels.
- Locate the circulator outputs in the control setup and verify the boiler circulator and System Pump/Aux outputs are configured to run with each priority that fires the boiler.
- Test: open all isolation valves, restore power and call for heat. Water temperature that climbs to the limit while the return stays cold confirms a flow problem. Temperature that behaves once the limit setting is raised confirms the setting was too tight.
- End at the fix: set the high limit at least 10 degrees F above the maximum target temperature plus the off differential, correct the piping or circulator setup, and if the burner is running hot, inspect the flame and run a combustion test at high fire with an analyzer and correct the settings.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Boiler circulator.
Parts that commonly fix the HIGH TEMP LIMIT code
- Boiler circulatorShop at Amazon