Weil-McLain Boiler ECO Tec 80/110/150/199 FLUE TEMP TOO HIGH Error Code

What the FLUE TEMP TOO HIGH code means

The flue temperature sensor has passed 210 degrees F, which is the warning level, or 220 degrees F, which is a lockout. Flue gas that hot means heat is not transferring into the water properly, usually from buildup in the heat exchanger or flue ways, or a vent problem. The fault resets automatically if the temperature drops below 210 degrees F for about two and a half minutes, and a rise above 220 degrees F needs a manual reset on the display.

Likely causes

  1. Buildup or abnormal wear in the heat exchanger, combustion chamber or flue ways
  2. Vent system wear or damage
  3. Faulty flue temperature sensor

How to fix it — step by step

  1. Record the display text and the flue temperature reading before resetting.
  2. Safety: switch the service switch off and close the gas shutoff before inspecting the heat exchanger or vent. Hot flue parts burn, so let the boiler cool first.
  3. Locate the flue temperature sensor in the flue outlet and follow the sensor diagnostic procedure for open and short conditions to rule the sensor in or out first.
  4. Test: a sensor whose resistance converts to a temperature that matches a thermometer at the flue is reading honestly, which makes the high temperature real. A reading that disagrees with the measured flue temperature condemns the sensor. → Shop the flue temperature sensor at Amazon
  5. End at the fix: inspect the heat exchanger, combustion chamber and flue ways for abnormal wear or buildup and the vent system for damage, and clean or repair what is found. If the sensor tested bad, replace the flue temperature sensor.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the FLUE TEMP TOO HIGH code

Parts run $25–$80
  • Flue temperature sensor$25–$80Shop at Amazon
  • Tools for this job, if you need them$10–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Weil-McLain Boiler ECO Tec 80/110/150/199 error codes