What the FLAME LOSS FAULT code means
The boiler went through five ignition attempts and the flame value dropped below proof of ignition during the stabilization time of ignition. The flame lights but cannot hold through the proving period, which is the pattern of a weak flame signal, a blocked vent or intake, or loose burner and venturi sealing. The fault behaves as a soft lockout cycle before settling into a manual lockout if the switch or flame problem stays open.
Likely causes
- Restricted or blocked flue pipe or intake pipe
- Loose burner fasteners or failed burner gaskets
- Wrong venturi or failed venturi gaskets, including propane models which use different venturis
- Fouled igniter or weak flame signal
- Incorrect combustion settings
How to fix it — step by step
- Record the display text and note at what point in the ignition sequence the flame drops out.
- Safety: switch the service switch off and close the gas shutoff before opening the burner compartment.
- Locate the burner fasteners and gaskets, the venturi and its gaskets, and the flue and intake pipes, and inspect each in turn.
- Test: check the flue and intake for restriction or blockage, confirm the correct venturi is fitted for the fuel in use, and check the flame signal during a firing attempt. A signal that collapses during stabilization with clear venting and sound gaskets points at the ignition and sensing parts.
- End at the fix: clear any vent or intake blockage, tighten or reseal the burner and replace failed gaskets, fit the correct venturi if the wrong one is installed, and clean or replace the igniter if the flame signal stays weak. → Shop the igniter at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Igniter.
Also tied to this fault: Burner gasket - Shop at Amazon
Parts that commonly fix the FLAME LOSS FAULT code
- Igniter$15–$85Shop at Amazon
- Burner gasketShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.