Weil-McLain Boiler ECO Tec 80/110/150/199 Air Pressure Switch Open
What this problem usually means
The air pressure switch connection is open, so the control cannot prove that combustion air is moving and will not proceed with ignition. The control soft-locks for four minutes, unlocks and checks again for up to four minutes, repeats that cycle once more, and then goes to a manual lockout if the switch is still open. A blocked vent or intake is the first thing to rule out.
Likely causes
- Blocked or restricted vent or intake piping
- Failed air pressure switch
- Loose or damaged pressure switch tubing or wiring
- Condensate or debris affecting the switch sensing lines
How to fix it — step by step
- Record the display text and whether the blower runs during the attempt.
- Safety: switch the service switch off before opening panels or handling the pressure switch.
- Locate the air pressure switch inside the boiler and follow its sensing tubes to the blower outlet and vent connection points.
- Test: inspect the vent and intake pipes for blockage first. Clear venting with a switch that still reads open on a running blower, checked with the tubes and wiring confirmed sound, condemns the switch.
- End at the fix: clear any vent or intake blockage found. If the venting is clear and connections are sound, replace the air pressure switch. → Shop the air pressure switch at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Air pressure switch.
Parts that commonly fix it
- Air pressure switch$50–$205Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.