Viessmann Vitodens 100-W Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 30 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| 0A | Fault 0A blocks the burner because a safety device connected to the boiler has responded. One form is the CO… | CO limiter responded, CO concentration too high | › |
| 0C | Fault 0C blocks the burner because the mains voltage supplying the boiler is too low. This is a power supply… | Mains voltage too low | › |
| 10 | Fault 10 puts the boiler into continuous operation because the outside temperature sensor is short circuited.… | Short circuit in the outside temperature sensor | › |
| 18 | Fault 18 puts the boiler into continuous operation because there is a lead break in the outside temperature… | Lead break in the outside temperature sensor | › |
| 30 | Fault 30 blocks the burner because the boiler water temperature sensor is short circuited. The control cannot… | Short circuit in the boiler water temperature sensor | › |
| 38 | Fault 38 blocks the burner because there is a lead break in the boiler water temperature sensor circuit. With… | Lead break in the boiler water temperature sensor | › |
| 50 | Fault 50 stops domestic hot water heating because the cylinder temperature sensor is short circuited. Space… | Short circuit in the cylinder temperature sensor | › |
| 51 | Fault 51 stops domestic hot water heating because the outlet temperature sensor is short circuited. The… | Short circuit in the outlet temperature sensor | › |
| 52 | Fault 52 blocks the burner because the flow sensor is short circuited. The control uses the flow sensor to… | Short circuit in the flow sensor | › |
| 58 | Fault 58 stops domestic hot water heating because there is a lead break in the cylinder temperature sensor… | Lead break in the cylinder temperature sensor | › |
| 59 | Fault 59 stops domestic hot water heating because there is a lead break in the outlet temperature sensor… | Lead break in the outlet temperature sensor | › |
| 5A | Fault 5A blocks the burner because there is a lead break in the flow sensor circuit. The control cannot prove… | Lead break in the flow sensor | › |
| A3 | Fault A3 blocks the burner because the flue gas temperature sensor is incorrectly positioned. The sensor is… | Flue gas temperature sensor incorrectly positioned | › |
| A9 | Fault A9 is a communication error with the OpenTherm device, and the boiler runs in control mode without it.… | Communication error with the OpenTherm device | › |
| b0 | Fault b0 blocks the burner because the flue gas temperature sensor is short circuited. Flue temperature is a… | Short circuit in the flue gas temperature sensor | › |
| b7 | Fault b7 is a burner control unit fault and puts the boiler into emergency mode. This is an internal fault of… | Burner control unit fault | › |
| b8 | Fault b8 blocks the burner because there is a lead break in the flue gas temperature sensor circuit. With no… | Lead break in the flue gas temperature sensor | › |
| E3 | Fault E3 puts the burner in a fault state because there is a fault in the safety chain. The safety chain… | Fault in the safety chain | › |
| E5 | Fault E5 blocks the burner as an internal fault, and the first check is the ionisation electrode and its… | Internal fault | › |
| F0 | Fault F0 blocks the burner as an internal fault of the control unit. There is no external sensor check for… | Internal fault in the control unit | › |
| F1 | Fault F1 puts the burner in a fault state because the maximum flue gas temperature has been exceeded. High… | Maximum flue gas temperature exceeded | › |
| F2 | Fault F2 puts the burner in a fault state because the temperature limiter has responded. The boiler… | Temperature limiter has responded | › |
| F3 | Fault F3 puts the burner in a fault state because a flame signal is already present at burner start, before… | Flame signal already present at burner start | › |
| F4 | Fault F4 puts the burner in a fault state because there is no flame signal when the burner tries to light.… | No flame signal present | › |
| F8 | Fault F8 puts the burner in a fault state because the fuel valve, the combination gas valve, closes too late… | Combination gas valve closes too late | › |
| F9 | Fault F9 puts the burner in a fault state because the fan speed is too low during burner start. The fan has… | Fan speed too low during burner start | › |
| FA | Fault FA puts the burner in a fault state because the fan idle state is not reached: the fan does not come to… | Fan idle state not reached, fan not at standstill | › |
| FC | Fault FC blocks the burner because the electrical fan control in the control unit is faulty. The fan itself… | Electrical fan control in the control unit faulty | › |
| Fd | Fault Fd blocks the burner as a burner control unit fault. The checks before condemning the control are the… | Burner control unit fault | › |
| FF | Fault FF blocks the burner as a burner control unit fault, with the same checks as Fd: ignition electrodes… | Burner control unit fault | › |
All Viessmann boiler models & codes →
Looking for a part?
Once you know the part you need, browse Viessmann Vitodens 100-W replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.