Viessmann Boiler Vitodens 100-W E3 Error Code
What the E3 code means
Fault E3 puts the burner in a fault state because there is a fault in the safety chain. The safety chain includes the temperature limiter and its connecting leads, and any break or trip in that chain stops the burner. This is a safety circuit fault and needs methodical testing, not repeated resets.
Likely causes
- Fault in the safety chain
- Temperature limiter tripped or faulty
- Break in the safety chain connecting leads
How to fix it — step by step
- Record the code before resetting: write down fault code E3 exactly as shown on the Vitodens 100-W display, and note whether the display calls the burner blocked or in a fault state.
- Safety: turn the boiler off at its ON/OFF switch and isolate power before removing the front cover or touching sensor wiring. Do not work on the gas train, burner or flue unless you are a qualified heating contractor.
- Locate the parts: the temperature limiter is fitted on the boiler, wired in the safety chain to the control unit, and fault E3 is read on the control unit display.
- Test: check the temperature limiter and its connecting leads for continuity and for a tripped limiter. A chain that tests continuous with a reset, healthy limiter and still shows E3 moves the pinpoint to the control unit, which is replaced if required. → Shop the control unit at Amazon
- End at the fix: correct the pinpointed cause, then press Reset by tapping and holding R for about 2 seconds. If E3 returns straight away, the pinpointed part is the cause and needs replacement by a contractor.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Temperature limiter.
Shop the Temperature limiter at Amazon
Also tied to this fault: Control unit - Shop at Amazon
Parts that commonly fix the E3 code
- Temperature limiterShop at Amazon
- Control unitShop at Amazon
- Tools for this job, if you need them$15–$65
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.