Viessmann Boiler Vitodens 100-W b8 Error Code
What the b8 code means
Fault b8 blocks the burner because there is a lead break in the flue gas temperature sensor circuit. With no flue temperature signal, the control blocks the burner for safety. The break is in the sensor or its lead.
Likely causes
- Lead break in the flue gas temperature sensor
- Broken or disconnected sensor lead
How to fix it — step by step
- Record the code before resetting: write down fault code b8 exactly as shown on the Vitodens 100-W display, and note whether the display calls the burner blocked or in a fault state.
- Safety: turn the boiler off at its ON/OFF switch and isolate power before removing the front cover or touching sensor wiring. Do not work on the gas train, burner or flue unless you are a qualified heating contractor.
- Locate the part: the flue gas temperature sensor sits in the flue gas path at the boiler and is wired to the control unit, where fault b8 is displayed.
- Test: check the flue gas temperature sensor and its lead for an open circuit. An open reading at the sensor itself condemns it; a good sensor means the lead or a terminal is open.
- End at the fix: correct the pinpointed cause, then press Reset by tapping and holding R for about 2 seconds. If b8 returns straight away, the pinpointed part is the cause and needs replacement by a contractor.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Flue gas temperature sensor.
Parts that commonly fix the b8 code
- Flue gas temperature sensor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.