Viessmann Boiler Vitodens 100-W 52 Error Code
What the 52 code means
Fault 52 blocks the burner because the flow sensor is short circuited. The control uses the flow sensor to prove water movement, and a shorted signal blocks operation. Check the connections and lead first, and replace the sensor if they are sound.
Likely causes
- Short circuit in the flow sensor
- Shorted sensor connections or lead
How to fix it — step by step
- Record the code before resetting: write down fault code 52 exactly as shown on the Vitodens 100-W display, and note whether the display calls the burner blocked or in a fault state.
- Safety: turn the boiler off at its ON/OFF switch and isolate power before removing the front cover or touching sensor wiring. Do not work on the gas train, burner or flue unless you are a qualified heating contractor.
- Locate the part: the flow sensor is fitted in the boiler waterway and wired to the control unit, where fault 52 is displayed.
- Test: check the flow sensor connections and lead for damage, moisture or a short. Clean, sound connections with a short still present condemn the flow sensor itself.
- End at the fix: correct the pinpointed cause, then press Reset by tapping and holding R for about 2 seconds. If 52 returns straight away, the pinpointed part is the cause and needs replacement by a contractor.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Flow sensor.
Parts that commonly fix the 52 code
- Flow sensorShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.