Viessmann Boiler Vitodens 100-W FC Error Code
What the FC code means
Fault FC blocks the burner because the electrical fan control in the control unit is faulty. The fan itself may be sound; the control output that drives it has failed. Check the fan connecting cable first, and replace the cable or the control unit as the checks require.
Likely causes
- Electrical fan control in the control unit faulty
- Faulty fan connecting cable
How to fix it — step by step
- Record the code before resetting: write down fault code FC exactly as shown on the Vitodens 100-W display, and note whether the display calls the burner blocked or in a fault state.
- Safety: turn the boiler off at its ON/OFF switch and isolate power before removing the front cover or touching sensor wiring. Do not work on the gas train, burner or flue unless you are a qualified heating contractor.
- Locate the parts: the fan connecting cable runs between the combustion fan and the control unit inside the boiler, and fault FC is read on the control unit display.
- Test: check the fan connecting cable for damage or loose terminals and prove it end to end. A sound cable with FC returning pinpoints the fan control inside the control unit, which means control unit replacement by a contractor.
- End at the fix: correct the pinpointed cause, then press Reset by tapping and holding R for about 2 seconds. If FC returns straight away, the pinpointed part is the cause and needs replacement by a contractor.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Control unit.
Shop the Control unit at Amazon
Also tied to this fault: Fan connecting cable - Shop at Amazon
Parts that commonly fix the FC code
- Control unitShop at Amazon
- Fan connecting cableShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.