Viessmann Boiler Vitodens 100-W 10 Error Code
What the 10 code means
Fault 10 puts the boiler into continuous operation because the outside temperature sensor is short circuited. With the sensor shorted, the control cannot read a real outdoor temperature, so it runs in constant mode instead of weather compensated control. Heating continues, but control accuracy is lost.
Likely causes
- Short circuit in the outside temperature sensor
- Shorted sensor lead
How to fix it — step by step
- Record the code before resetting: write down fault code 10 exactly as shown on the Vitodens 100-W display, and note whether the display calls the burner blocked or in a fault state.
- Safety: turn the boiler off at its ON/OFF switch and isolate power before removing the front cover or touching sensor wiring. Do not work on the gas train, burner or flue unless you are a qualified heating contractor.
- Locate the part: the outside temperature sensor is mounted on an outside wall of the building and wired back to the boiler control unit, where fault 10 is displayed.
- Test: check the outside temperature sensor and its lead for a short, including damaged insulation or water in the connection. A sensor and lead that test clean rule out the short and point to the connection at the control unit.
- End at the fix: correct the pinpointed cause, then press Reset by tapping and holding R for about 2 seconds. If 10 returns straight away, the pinpointed part is the cause and needs replacement by a contractor.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Outside temperature sensor.
Parts that commonly fix the 10 code
- Outside temperature sensor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.