Viessmann Boiler Vitodens 100-W Fd Error Code
What the Fd code means
Fault Fd blocks the burner as a burner control unit fault. The checks before condemning the control are the ignition electrodes and their connecting cables, and whether a strong interference (EMC) field exists near the appliance. If the fault persists after those checks and a reset, the control unit is replaced.
Likely causes
- Burner control unit fault
- Ignition electrode or connecting cable fault
- Strong EMC interference field near the appliance
How to fix it — step by step
- Record the code before resetting: write down fault code Fd exactly as shown on the Vitodens 100-W display, and note whether the display calls the burner blocked or in a fault state.
- Safety: turn the boiler off at its ON/OFF switch and isolate power before removing the front cover or touching sensor wiring. Do not work on the gas train, burner or flue unless you are a qualified heating contractor.
- Locate the parts: the ignition electrodes are in the burner assembly, their cables run to the burner control unit, and fault Fd is read on the control unit display.
- Test: check the ignition electrodes and connecting cables, and look for a strong interference source near the boiler that can be corrected. Clean electrodes, sound cables and no interference with Fd persisting pinpoint the burner control unit.
- End at the fix: correct the pinpointed cause, then press Reset by tapping and holding R for about 2 seconds. If Fd returns straight away, the pinpointed part is the cause and needs replacement by a contractor.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Burner control unit.
Shop the Burner control unit at Amazon
Also tied to this fault: Ignition electrode - Shop at Amazon
Parts that commonly fix the Fd code
- Burner control unitShop at Amazon
- Ignition electrodeShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.