Viessmann Boiler Vitodens 100-W 18 Error Code
What the 18 code means
Fault 18 puts the boiler into continuous operation because there is a lead break in the outside temperature sensor circuit. The control has lost the outdoor temperature signal completely, so it falls back to constant operation. The burner is not blocked, but weather compensation is lost.
Likely causes
- Lead break in the outside temperature sensor
- Broken or disconnected sensor lead
How to fix it — step by step
- Record the code before resetting: write down fault code 18 exactly as shown on the Vitodens 100-W display, and note whether the display calls the burner blocked or in a fault state.
- Safety: turn the boiler off at its ON/OFF switch and isolate power before removing the front cover or touching sensor wiring. Do not work on the gas train, burner or flue unless you are a qualified heating contractor.
- Locate the part: the outside temperature sensor sits on an outside wall and connects by its lead to the boiler control unit, where fault 18 is displayed.
- Test: check the outside temperature sensor and its lead end to end for a break or a loose terminal. Continuity restored and a correct sensor reading clear the fault; a sensor that reads open on its own terminals has failed and is the pinpoint. → Shop the outside temperature sensor at Amazon
- End at the fix: correct the pinpointed cause, then press Reset by tapping and holding R for about 2 seconds. If 18 returns straight away, the pinpointed part is the cause and needs replacement by a contractor.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Outside temperature sensor.
Parts that commonly fix the 18 code
- Outside temperature sensor$25–$80Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.