Viessmann Boiler Vitodens 100-W 50 Error Code

What the 50 code means

Fault 50 stops domestic hot water heating because the cylinder temperature sensor is short circuited. Space heating can continue, but the control cannot read the stored hot water temperature, so DHW heating is disabled. The fault is in the cylinder sensor or its lead.

Likely causes

  1. Short circuit in the cylinder temperature sensor
  2. Shorted sensor lead

How to fix it — step by step

  1. Record the code before resetting: write down fault code 50 exactly as shown on the Vitodens 100-W display, and note whether the display calls the burner blocked or in a fault state.
  2. Safety: turn the boiler off at its ON/OFF switch and isolate power before removing the front cover or touching sensor wiring. Do not work on the gas train, burner or flue unless you are a qualified heating contractor.
  3. Locate the part: the cylinder temperature sensor is fitted in the hot water cylinder and wired back to the boiler control unit, where fault 50 is displayed.
  4. Test: check the cylinder temperature sensor and its lead for a short. A short that remains with the sensor disconnected is a lead fault; a short at the sensor terminals condemns the sensor.
  5. End at the fix: correct the pinpointed cause, then press Reset by tapping and holding R for about 2 seconds. If 50 returns straight away, the pinpointed part is the cause and needs replacement by a contractor.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 50 code

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.