Viessmann Boiler Vitodens 100-W 58 Error Code

What the 58 code means

Fault 58 stops domestic hot water heating because there is a lead break in the cylinder temperature sensor circuit. The control cannot see the stored water temperature, so it will not heat the cylinder. Space heating is not the blocked function here; the DHW sensor circuit is.

Likely causes

  1. Lead break in the cylinder temperature sensor
  2. Broken or disconnected sensor lead

How to fix it — step by step

  1. Record the code before resetting: write down fault code 58 exactly as shown on the Vitodens 100-W display, and note whether the display calls the burner blocked or in a fault state.
  2. Safety: turn the boiler off at its ON/OFF switch and isolate power before removing the front cover or touching sensor wiring. Do not work on the gas train, burner or flue unless you are a qualified heating contractor.
  3. Locate the part: the cylinder temperature sensor is in the hot water cylinder, wired back to the boiler control unit where fault 58 is displayed.
  4. Test: check the cylinder sensor and its lead end to end for an open circuit. A sensor reading open at its terminals is the pinpoint; a good sensor means the break is in the lead or a terminal.
  5. End at the fix: correct the pinpointed cause, then press Reset by tapping and holding R for about 2 seconds. If 58 returns straight away, the pinpointed part is the cause and needs replacement by a contractor.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 58 code

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.