Viessmann Boiler Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 30 codes covered.
Finding your model number: it is on the rating plate on the boiler jacket, often behind the front panel.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
Vitodens 100-W (two-character fault codes)
Faults show as two-character codes on the boiler display (0A and its siblings); the service instructions' fault table gives each code's cause and remedy.
| Code | What it means | Check first | |
|---|---|---|---|
| 0A | Fault 0A blocks the burner because a safety device connected to the boiler has responded. One form is the CO… | CO limiter responded, CO concentration too high | › |
| 0C | Fault 0C blocks the burner because the mains voltage supplying the boiler is too low. This is a power supply… | Mains voltage too low | › |
| 10 | Fault 10 puts the boiler into continuous operation because the outside temperature sensor is short circuited.… | Short circuit in the outside temperature sensor | › |
| 18 | Fault 18 puts the boiler into continuous operation because there is a lead break in the outside temperature… | Lead break in the outside temperature sensor | › |
| 30 | Fault 30 blocks the burner because the boiler water temperature sensor is short circuited. The control cannot… | Short circuit in the boiler water temperature sensor | › |
| 38 | Fault 38 blocks the burner because there is a lead break in the boiler water temperature sensor circuit. With… | Lead break in the boiler water temperature sensor | › |
| 50 | Fault 50 stops domestic hot water heating because the cylinder temperature sensor is short circuited. Space… | Short circuit in the cylinder temperature sensor | › |
| 51 | Fault 51 stops domestic hot water heating because the outlet temperature sensor is short circuited. The… | Short circuit in the outlet temperature sensor | › |
| 52 | Fault 52 blocks the burner because the flow sensor is short circuited. The control uses the flow sensor to… | Short circuit in the flow sensor | › |
| 58 | Fault 58 stops domestic hot water heating because there is a lead break in the cylinder temperature sensor… | Lead break in the cylinder temperature sensor | › |
| 59 | Fault 59 stops domestic hot water heating because there is a lead break in the outlet temperature sensor… | Lead break in the outlet temperature sensor | › |
| 5A | Fault 5A blocks the burner because there is a lead break in the flow sensor circuit. The control cannot prove… | Lead break in the flow sensor | › |
| A3 | Fault A3 blocks the burner because the flue gas temperature sensor is incorrectly positioned. The sensor is… | Flue gas temperature sensor incorrectly positioned | › |
| A9 | Fault A9 is a communication error with the OpenTherm device, and the boiler runs in control mode without it.… | Communication error with the OpenTherm device | › |
| b0 | Fault b0 blocks the burner because the flue gas temperature sensor is short circuited. Flue temperature is a… | Short circuit in the flue gas temperature sensor | › |
| b7 | Fault b7 is a burner control unit fault and puts the boiler into emergency mode. This is an internal fault of… | Burner control unit fault | › |
| b8 | Fault b8 blocks the burner because there is a lead break in the flue gas temperature sensor circuit. With no… | Lead break in the flue gas temperature sensor | › |
| E3 | Fault E3 puts the burner in a fault state because there is a fault in the safety chain. The safety chain… | Fault in the safety chain | › |
| E5 | Fault E5 blocks the burner as an internal fault, and the first check is the ionisation electrode and its… | Internal fault | › |
| F0 | Fault F0 blocks the burner as an internal fault of the control unit. There is no external sensor check for… | Internal fault in the control unit | › |
| F1 | Fault F1 puts the burner in a fault state because the maximum flue gas temperature has been exceeded. High… | Maximum flue gas temperature exceeded | › |
| F2 | Fault F2 puts the burner in a fault state because the temperature limiter has responded. The boiler… | Temperature limiter has responded | › |
| F3 | Fault F3 puts the burner in a fault state because a flame signal is already present at burner start, before… | Flame signal already present at burner start | › |
| F4 | Fault F4 puts the burner in a fault state because there is no flame signal when the burner tries to light.… | No flame signal present | › |
| F8 | Fault F8 puts the burner in a fault state because the fuel valve, the combination gas valve, closes too late… | Combination gas valve closes too late | › |
| F9 | Fault F9 puts the burner in a fault state because the fan speed is too low during burner start. The fan has… | Fan speed too low during burner start | › |
| FA | Fault FA puts the burner in a fault state because the fan idle state is not reached: the fan does not come to… | Fan idle state not reached, fan not at standstill | › |
| FC | Fault FC blocks the burner because the electrical fan control in the control unit is faulty. The fan itself… | Electrical fan control in the control unit faulty | › |
| Fd | Fault Fd blocks the burner as a burner control unit fault. The checks before condemning the control are the… | Burner control unit fault | › |
| FF | Fault FF blocks the burner as a burner control unit fault, with the same checks as Fd: ignition electrodes… | Burner control unit fault | › |
Common questions
What does fault 0A mean on a Viessmann Vitodens 100-W?
A safety device connected to the boiler has responded and is blocking the burner. The fault table's checks work through the connected safety devices and their wiring before the control is suspected.
Once you know the part you need, browse Viessmann Boiler replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.