Viessmann Boiler Vitodens 100-W 5A Error Code

What the 5A code means

Fault 5A blocks the burner because there is a lead break in the flow sensor circuit. The control cannot prove flow from a broken signal, so the burner stays blocked. Connections and lead are checked first, and the sensor is replaced if they are sound.

Likely causes

  1. Lead break in the flow sensor
  2. Broken sensor connections or lead

How to fix it — step by step

  1. Record the code before resetting: write down fault code 5A exactly as shown on the Vitodens 100-W display, and note whether the display calls the burner blocked or in a fault state.
  2. Safety: turn the boiler off at its ON/OFF switch and isolate power before removing the front cover or touching sensor wiring. Do not work on the gas train, burner or flue unless you are a qualified heating contractor.
  3. Locate the part: the flow sensor is fitted in the boiler waterway and connected to the control unit, where fault 5A is displayed.
  4. Test: check the flow sensor connections and lead for a break or loose terminal. A sensor that tests open on its own is the pinpoint; a good sensor shifts the fault to the lead.
  5. End at the fix: correct the pinpointed cause, then press Reset by tapping and holding R for about 2 seconds. If 5A returns straight away, the pinpointed part is the cause and needs replacement by a contractor.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 5A code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.