Viessmann Boiler Vitodens 100-W 0A Error Code
What the 0A code means
Fault 0A blocks the burner because a safety device connected to the boiler has responded. One form is the CO limiter responding because the carbon monoxide concentration is too high, and the other is the gas pressure switch responding because the gas pressure is too low. The boiler will not run until the device that tripped is found and its cause is removed.
Likely causes
- CO limiter responded, CO concentration too high
- Gas pressure switch responded, gas pressure too low
How to fix it — step by step
- Record the code before resetting: write down fault code 0A exactly as shown on the Vitodens 100-W display, and note whether the display calls the burner blocked or in a fault state.
- Safety: turn the boiler off at its ON/OFF switch and isolate power before removing the front cover or touching sensor wiring. Do not work on the gas train, burner or flue unless you are a qualified heating contractor.
- Locate the parts: the CO limiter and the gas pressure switch, where fitted, are safety devices wired into the boiler, and the code itself is read on the control unit display behind the front flap.
- Test: check the heating system for the cause of escaping CO, and check the gas supply pressure where a gas pressure switch has responded. A boiler that still shows 0A with a proven gas supply and no CO cause has a tripped or faulty safety device in that chain, which a contractor must test individually.
- End at the fix: correct the pinpointed cause, then press Reset by tapping and holding R for about 2 seconds. If 0A returns straight away, the pinpointed part is the cause and needs replacement by a contractor.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the CO limiter.
Also tied to this fault: Gas pressure switch - Shop at Amazon
Parts that commonly fix the 0A code
- CO limiterShop at Amazon
- Gas pressure switch$50–$205Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.