Viessmann Boiler Vitodens 100-W FF Error Code
What the FF code means
Fault FF blocks the burner as a burner control unit fault, with the same checks as Fd: ignition electrodes and connecting cables first, and any strong interference (EMC) field near the appliance corrected. A fault that persists after reset means the control unit is replaced.
Likely causes
- Burner control unit fault
- Ignition electrode or connecting cable fault
- Strong EMC interference field near the appliance
How to fix it — step by step
- Record the code before resetting: write down fault code FF exactly as shown on the Vitodens 100-W display, and note whether the display calls the burner blocked or in a fault state.
- Safety: turn the boiler off at its ON/OFF switch and isolate power before removing the front cover or touching sensor wiring. Do not work on the gas train, burner or flue unless you are a qualified heating contractor.
- Locate the parts: the ignition electrodes sit in the burner assembly with cables to the burner control unit, and fault FF is read on the control unit display.
- Test: check the ignition electrodes and connecting cables and remove any strong interference source near the boiler. Everything external proven sound with FF returning pinpoints the burner control unit for replacement.
- End at the fix: correct the pinpointed cause, then press Reset by tapping and holding R for about 2 seconds. If FF returns straight away, the pinpointed part is the cause and needs replacement by a contractor.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Burner control unit.
Shop the Burner control unit at Amazon
Also tied to this fault: Ignition electrode - Shop at Amazon
Parts that commonly fix the FF code
- Burner control unitShop at Amazon
- Ignition electrodeShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.