Viessmann Boiler Vitodens 100-W E5 Error Code

What the E5 code means

Fault E5 blocks the burner as an internal fault, and the first check is the ionisation electrode and its connecting cables. Flame detection runs through that electrode, so a bad electrode or cable can present as this internal fault. Press Reset after the check, and treat a returning E5 as a deeper control problem.

Likely causes

  1. Internal fault
  2. Faulty ionisation electrode or connecting cable

How to fix it — step by step

  1. Record the code before resetting: write down fault code E5 exactly as shown on the Vitodens 100-W display, and note whether the display calls the burner blocked or in a fault state.
  2. Safety: turn the boiler off at its ON/OFF switch and isolate power before removing the front cover or touching sensor wiring. Do not work on the gas train, burner or flue unless you are a qualified heating contractor.
  3. Locate the part: the ionisation electrode is in the burner assembly, sensing the flame, with its connecting cable running to the control unit where fault E5 is displayed.
  4. Test: check the ionisation electrode for condition and its connecting cables for damage or loose terminals. A clean, correctly connected electrode with E5 returning after reset points inside the control, which is contractor work.
  5. End at the fix: correct the pinpointed cause, then press Reset by tapping and holding R for about 2 seconds. If E5 returns straight away, the pinpointed part is the cause and needs replacement by a contractor.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E5 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.