Goodman Air Conditioner Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 24 codes covered.
Shop Goodman Air Conditioner parts at RepairClinic or Amazon
All Air Conditioner codes across brands →
Finding your model number: it is on the unit's rating plate.
- 01 — Low pressure cut-out trip (also reported as a low side fault after very long run times), shown on the 7-segment display of the outdoor…
- 02 — High pressure cut-out trip (also reported as a high side fault after repeated compressor protector trips), shown on the 7-segment display…
- 03 — Short cycling, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage air…
- 04 — Locked rotor, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage air…
- 05 — Open circuit, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage air…
- 06 — Open start circuit, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage…
- 09 — Low pilot (secondary) voltage, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman…
- A2 — Outdoor air temperature sensor fault, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman…
- A3 — Outdoor coil temperature sensor fault, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman…
- AC leaking water inside — Goodman's system manuals pair the two indoor water causes directly: 'Water leaking — clogged condensate drain line, frozen evaporator…
- AC not cooling — Goodman's own owner-manual troubleshooting for 'unit not cooling' is a short, practical list: thermostat set incorrectly, a tripped circuit…
- AC short cycling — Goodman symptom references describe short cycling — turning on and off quickly — with a consistent cause list: a dirty coil, an oversized…
- AC won't turn on — Goodman's manuals reduce a no-start to three buckets: no power, a thermostat problem, or a tripped safety switch. The safety switch is the…
- Condenser fan not spinning — Goodman's service literature lists 'condenser fan will not start' as its own complaint line, separate from a compressor that will not start…
- d0 — Data not on network, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet…
- d1 — Invalid data on network, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet…
- E5 — Open fuse, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage air…
- EE — Board mis-operation, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet…
- Frozen evaporator coil — A Goodman coil freezes for the same two families of reasons as any split system: not enough warm air crossing the coil, or not enough…
- H8 — High line voltage, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage…
- L1 — Low pressure cut-out lockout (3 trips), shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman…
- L2 — High pressure cut-out lockout (3 trips), shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman…
- L8 — Low line voltage / no line voltage, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman…
- P0 — Compressor protector open, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet…