Goodman Air Conditioner P0 Error Code

What the P0 code means

Compressor protector open, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage air conditioners and heat pumps (GSXC/GSZC series, IOG-4009). No current is flowing through the run or start windings; the fault clears after 1 normal cycle and may require cycling 24 VAC to the control.

Likely causes

  1. Compressor run winding open
  2. Compressor not properly wired to the control / faulty compressor wiring
  3. Failed compressor run capacitor
  4. Faulty run capacitor wiring

How to fix it — step by step

  1. Turn power OFF before repair and let a hot compressor cool — an open internal protector resets when the compressor cools → Shop the compressor at RepairClinic
  2. Have a technician check the compressor windings, wiring and run capacitor → Shop the run capacitor at RepairClinic
  3. Replace faulty parts with the correct replacement parts