Goodman Air Conditioner P0 Error Code
What the P0 code means
Compressor protector open, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage air conditioners and heat pumps (GSXC/GSZC series, IOG-4009). No current is flowing through the run or start windings; the fault clears after 1 normal cycle and may require cycling 24 VAC to the control.
Likely causes
- Compressor run winding open
- Compressor not properly wired to the control / faulty compressor wiring
- Failed compressor run capacitor
- Faulty run capacitor wiring
How to fix it — step by step
- Turn power OFF before repair and let a hot compressor cool — an open internal protector resets when the compressor cools → Shop the compressor at RepairClinic
- Have a technician check the compressor windings, wiring and run capacitor → Shop the run capacitor at RepairClinic
- Replace faulty parts with the correct replacement parts
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Compressor.
Shop the Compressor at RepairClinic or Amazon
Also tied to this fault: Run capacitor - Shop at RepairClinic or Amazon
Parts that commonly fix the P0 code
- Compressor - Shop at RepairClinic or Amazon
- Run capacitor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.