Goodman Air Conditioner 06 Error Code

What the 06 code means

Open start circuit, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage air conditioners and heat pumps (GSXC/GSZC series, IOG-4009). The compressor and outdoor fan are off with both pressure switches closed; the fault clears after 1 normal cycle.

Likely causes

  1. Compressor start winding open
  2. Failed compressor run capacitor
  3. Faulty run capacitor wiring
  4. Compressor not properly wired to the control / faulty compressor wiring

How to fix it — step by step

  1. Turn power OFF before repair
  2. Have a technician check the compressor windings and test/replace the run capacitor → Shop the run capacitor at RepairClinic → Shop the compressor at RepairClinic
  3. Repair or replace faulty compressor wiring