Goodman Air Conditioner 01 Error Code

What the 01 code means

Low pressure cut-out trip (also reported as a low side fault after very long run times), shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage air conditioners and heat pumps (GSXC/GSZC series, IOG-4009). The compressor and outdoor fan are off while thermostat demand is present.

Likely causes

  1. Low refrigerant charge
  2. Restriction in the liquid line
  3. Indoor blower motor failure
  4. Indoor thermostat set extremely low

How to fix it — step by step

  1. Check the indoor thermostat setting and replace a dirty filter; confirm the indoor blower runs
  2. Turn power OFF before any repair
  3. Have a technician verify refrigerant charge, check for a restricted liquid line and test the low pressure switch → Shop the low pressure switch at RepairClinic

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 01 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.