Goodman Air Conditioner L2 Error Code

What the L2 code means

High pressure cut-out lockout (3 trips), shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage air conditioners and heat pumps (GSXC/GSZC series, IOG-4009). The low/high pressure lockout logic applies after the high pressure switch trips 3 times within the same thermostat demand; the fault must be cleared by cycling 24 VAC to the control.

Likely causes

  1. Blocked (dirty) condenser coil
  2. Outdoor fan not running — motor, wiring or capacitor failure → Shop the outdoor fan motor capacitor at RepairClinic

How to fix it — step by step

  1. Clean the condenser coil and restore outdoor fan operation first
  2. Have a technician verify refrigerant pressures before clearing the lockout
  3. Cycle 24 VAC to the control to clear the fault only after the cause is repaired

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the L2 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.