Goodman Air Conditioner 02 Error Code
What the 02 code means
High pressure cut-out trip (also reported as a high side fault after repeated compressor protector trips), shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage air conditioners and heat pumps (GSXC/GSZC series, IOG-4009). The compressor and outdoor fan are off while thermostat demand is present.
Likely causes
- Blocked (dirty) condenser coil
- Outdoor fan not running — motor, wiring or capacitor failure
How to fix it — step by step
- Turn the system off and clean the condenser coil
- Turn power OFF before repair and check the outdoor fan motor, its wiring and capacitor → Shop the outdoor fan motor capacitor at RepairClinic → Shop the outdoor fan motor at RepairClinic
- Replace faulty fan parts with the correct replacement parts; the fault clears after 4 consecutive normal cycles
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the High pressure switch.
Shop the High pressure switch at RepairClinic or Amazon
Also tied to this fault: Outdoor fan motor - Shop at RepairClinic or Amazon; Outdoor fan motor capacitor - Shop at RepairClinic or Amazon
Parts that commonly fix the 02 code
- High pressure switch - Shop at RepairClinic or Amazon
- Outdoor fan motor - Shop at RepairClinic or Amazon
- Outdoor fan motor capacitor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.