Goodman Air Conditioner L1 Error Code
What the L1 code means
Low pressure cut-out lockout (3 trips), shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage air conditioners and heat pumps (GSXC/GSZC series, IOG-4009). The low pressure switch tripped 3 times within the same thermostat demand; the fault must be cleared by cycling 24 VAC to the control.
Likely causes
- Low refrigerant charge
- Restriction in the liquid line
- Indoor blower motor failure
- Indoor thermostat set extremely low
How to fix it — step by step
- Do not repeatedly cycle 24 VAC to force restarts
- Have a technician verify refrigerant charge, check the liquid line for restriction and test the blower and low pressure switch → Shop the low pressure switch at RepairClinic
- Cycle 24 VAC to the control to clear the fault only after the cause is repaired
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Low pressure switch.
Shop the Low pressure switch at RepairClinic or Amazon
Also tied to this fault: Liquid line filter drier - Shop at RepairClinic or Amazon
Parts that commonly fix the L1 code
- Low pressure switch - Shop at RepairClinic or Amazon
- Liquid line filter drier - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.