Goodman Air Conditioner L1 Error Code

What the L1 code means

Low pressure cut-out lockout (3 trips), shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage air conditioners and heat pumps (GSXC/GSZC series, IOG-4009). The low pressure switch tripped 3 times within the same thermostat demand; the fault must be cleared by cycling 24 VAC to the control.

Likely causes

  1. Low refrigerant charge
  2. Restriction in the liquid line
  3. Indoor blower motor failure
  4. Indoor thermostat set extremely low

How to fix it — step by step

  1. Do not repeatedly cycle 24 VAC to force restarts
  2. Have a technician verify refrigerant charge, check the liquid line for restriction and test the blower and low pressure switch → Shop the low pressure switch at RepairClinic
  3. Cycle 24 VAC to the control to clear the fault only after the cause is repaired

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the L1 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.