Goodman Air Conditioner 04 Error Code
What the 04 code means
Locked rotor, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet two-stage air conditioners and heat pumps (GSXC/GSZC series, IOG-4009). The compressor protector tripped four consecutive times with an average run time between trips of less than 15 seconds; the fault must be cleared by cycling 24 VAC to the control.
Likely causes
- Compressor bearings seized
- Failed compressor run capacitor
- Faulty run capacitor wiring
- Low line voltage
How to fix it — step by step
- Turn the system off — repeated start attempts worsen compressor damage → Shop the compressor at RepairClinic
- Have a technician check compressor operation and test/replace the run capacitor and its wiring → Shop the run capacitor at RepairClinic
- Verify line voltage is within the rating plate range; contact the utility if it is out of range
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Compressor.
Shop the Compressor at RepairClinic or Amazon
Also tied to this fault: Run capacitor - Shop at RepairClinic or Amazon
Parts that commonly fix the 04 code
- Compressor - Shop at RepairClinic or Amazon
- Run capacitor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.