Goodman Air Conditioner d1 Error Code

What the d1 code means

Invalid data on network, shown on the 7-segment display of the outdoor unit's integrated (unitary) control board on Goodman ComfortNet communicating air conditioners and heat pumps (GSXC/GSZC series, IOG-4009). The integrated control contains invalid shared data, or network data is invalid for the control, so the unit fails to operate.

Likely causes

  1. Invalid shared data loaded into the outdoor control
  2. Network data invalid for this integrated control module

How to fix it — step by step

  1. Verify the system type (communicating or legacy)
  2. Have a technician populate the correct shared data using the memory card for the specific model, or wire the system as a legacy system
  3. The error clears once correct data is loaded