Coleman Furnace Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 16 problems covered.
Finding your model number: it is inside the blower/burner compartment door.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
268897-UUM-B control (Johnson Controls)
| Problem | What it means | Check first | |
|---|---|---|---|
| 1 red flash | Flame was sensed when there was no call for heat. The control turns on both the inducer motor and the supply… | Gas valve leaking through | › |
| 10 red flashes | Gas flow with no call for heat. The control is reporting gas moving when the valve should be shut. | Gas valve passing gas with no call | › |
| 11 red flashes | A primary or auxiliary limit switch has stayed open for more than five minutes. With no airflow, the heat has… | Failed blower motor | › |
| 12 red flashes | Open igniter circuit. The control cannot pass current through the igniter. | Disconnected or loose igniter wire | › |
| 2 red flashes | The normally open pressure switch contacts are stuck in the closed position. | Faulty pressure switch with contacts stuck closed | › |
| 3 red flashes | The pressure switch contact did not close after the inducer was energized, so the ignition sequence stops. | Faulty inducer motor | › |
| 4 amber flashes | The control board is receiving a Y signal from the thermostat without a G signal. That means the thermostat… | Thermostat wired so Y is connected without G | › |
| 4 red flashes | A primary or auxiliary limit switch has opened. The furnace overheated, and the control runs the supply air… | Dirty filter restricting airflow | › |
| 5 red flashes | The rollout switch has opened. The rollout control is manually reset, and this fault means flame or heat… | Poor combustion air supply | › |
| 6 red flashes | After the unit was operating, the pressure switch opened 4 times during the call for heat. The furnace locks… | Vent or intake partially blocked so draft fades mid cycle | › |
| 7 red flashes | Flame could not be established. The no light condition occurred 3 times during the call for heat, and the… | Low gas pressure | › |
| 8 red flashes | Flame was lost 5 times during the heating cycle. The furnace locks out for one hour and then restarts. | Low gas pressure | › |
| 9 red flashes | Reversed line voltage polarity, or a grounding problem. Both heating and cooling operation are affected. | Line voltage polarity reversed at the furnace or the branch circuit | › |
| Rapid amber flash | Flame sense current is below 1.5 microamps. The furnace runs, but the flame signal is weak. | Dirty or oxidized flame sensor | › |
| Rapid red flash | Twinning error, or incorrect 24 volt phasing. The control is reporting a wiring or phasing problem, most… | Twinning wiring error on a twinned pair of furnaces | › |
| Steady on red | Control failure. The failure is internal to the control, and the control should be replaced. | Internal failure inside the furnace control | › |