Coleman Furnace 268897-UUM-B control (Johnson Controls) 1 red flash
What this problem usually means
Flame was sensed when there was no call for heat. The control turns on both the inducer motor and the supply air blower on this fault.
Likely causes
- Gas valve leaking through
- Gas valve slow to close after the call ends
How to fix it — step by step
- Turn the power off and close the gas shutoff to the furnace. With this code the control runs both the inducer and the supply air blower, which is normal for the fault.
- If you smell gas, leave the building and call the gas supplier from outside.
- Confirm the burners are fully out. The manual names a gas valve that leaks through or is slow closing as the typical cause.
- Do not reset and run this furnace. A leaking gas valve is replaced by a pro, not repaired.
- Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the gas valve.
Parts that commonly fix it
- gas valve$100–$355Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Coleman Furnace 268897-UUM-B control (Johnson Controls) problems
- 10 red flashes
- 11 red flashes
- 12 red flashes
- 2 red flashes
- 3 red flashes
- 4 amber flashes
- 4 red flashes
- 5 red flashes
- 6 red flashes
- 7 red flashes
- 8 red flashes
- 9 red flashes
See all Coleman 268897-UUM-B control (Johnson Controls) codes & guides →