Coleman Furnace 268897-UUM-B control (Johnson Controls) 5 red flashes
What this problem usually means
The rollout switch has opened. The rollout control is manually reset, and this fault means flame or heat escaped the burner compartment.
Likely causes
- Poor combustion air supply
- Inducer not operating properly
- Primary heat exchanger failure
- Burner problem causing flame rollout
How to fix it — step by step
- Turn the power off and close the gas shutoff. The rollout control is manually reset, but do not reset it until the cause is found. Rollout means flame escaped the burners.
- Look above the burners for scorch marks or melted wire insulation. Damage there confirms the event.
- Check that combustion air openings to the furnace space are open and not blocked by stored items.
- Restore power for a test call and confirm the inducer starts and pulls draft.
- Find the rollout switch above the burners, reset it by hand, and cycle power to the control as the manual directs, only after the checks above pass.
- If the switch trips again, stop and call a pro. The manual lists heat exchanger failure as a cause, and that ends the life of the furnace.
- Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the rollout switch.
Parts that commonly fix it
- rollout switch$5–$35Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Coleman Furnace 268897-UUM-B control (Johnson Controls) problems
- 6 red flashes
- 7 red flashes
- 8 red flashes
- 9 red flashes
- Rapid amber flash
- Rapid red flash
- Steady on red
- 1 red flash
- 10 red flashes
- 11 red flashes
- 12 red flashes
- 2 red flashes
See all Coleman 268897-UUM-B control (Johnson Controls) codes & guides →