Coleman Furnace 268897-UUM-B control (Johnson Controls) 4 red flashes

What this problem usually means

A primary or auxiliary limit switch has opened. The furnace overheated, and the control runs the supply air blower and inducer while the fault is active.

Likely causes

  1. Dirty filter restricting airflow
  2. Improperly sized duct system
  3. Incorrect blower speed setting
  4. Incorrect firing rate
  5. Faulty blower motor

How to fix it — step by step

  1. On this fault the control operates the supply air blower and the inducer to cool the furnace. Let it run until it stops.
  2. Turn the power off and replace a dirty air filter.
  3. Open closed registers and clear return grilles. Check that furniture or rugs are not covering returns.
  4. Restore power and call for heat. Confirm the blower runs at the correct heat speed. The speed is set by a wire tap on the control board, and a tap set too low overheats the furnace.
  5. If the blower is weak or dead, the motor is the suspect part. If airflow and blower check out and trips repeat, call a pro to verify firing rate and test the limit switches, since the manual lists firing rate as a cause and that is gas work.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $5–$450Typical pro repair $150–$2,000

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.