Coleman Furnace 268897-UUM-B control (Johnson Controls) 4 red flashes
What this problem usually means
A primary or auxiliary limit switch has opened. The furnace overheated, and the control runs the supply air blower and inducer while the fault is active.
Likely causes
- Dirty filter restricting airflow
- Improperly sized duct system
- Incorrect blower speed setting
- Incorrect firing rate
- Faulty blower motor
How to fix it — step by step
- On this fault the control operates the supply air blower and the inducer to cool the furnace. Let it run until it stops.
- Turn the power off and replace a dirty air filter.
- Open closed registers and clear return grilles. Check that furniture or rugs are not covering returns.
- Restore power and call for heat. Confirm the blower runs at the correct heat speed. The speed is set by a wire tap on the control board, and a tap set too low overheats the furnace.
- If the blower is weak or dead, the motor is the suspect part. If airflow and blower check out and trips repeat, call a pro to verify firing rate and test the limit switches, since the manual lists firing rate as a cause and that is gas work.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the air filter.
Also tied to this fault: blower motor - Shop at Amazon; limit switch - Shop at Amazon
Parts that commonly fix it
- air filter$5–$30Shop at Amazon
- blower motor$95–$450Shop at Amazon
- limit switch$5–$35Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Coleman Furnace 268897-UUM-B control (Johnson Controls) problems
- 5 red flashes
- 6 red flashes
- 7 red flashes
- 8 red flashes
- 9 red flashes
- Rapid amber flash
- Rapid red flash
- Steady on red
- 1 red flash
- 10 red flashes
- 11 red flashes
- 12 red flashes
See all Coleman 268897-UUM-B control (Johnson Controls) codes & guides →