Coleman Furnace 268897-UUM-B control (Johnson Controls) 12 red flashes
What this problem usually means
Open igniter circuit. The control cannot pass current through the igniter.
Likely causes
- Disconnected or loose igniter wire
- Cracked or broken igniter
How to fix it — step by step
- Turn the power off before touching the igniter. It is fragile and runs extremely hot.
- Remove the burner door and find the igniter in front of the burners. Follow its wires to the plug and reseat any loose connection.
- Inspect the element for a crack or a break. Any visible damage means the igniter has failed.
- Test the igniter with a meter set to ohms with the plug off. An open reading confirms it.
- Replace a failed igniter with the correct part, holding the new one by its base only.
- Verify the fix: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the hot surface ignitor.
Parts that commonly fix it
- hot surface ignitorShop at Amazon
- Tools for this job, if you need them$15–$65
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Coleman Furnace 268897-UUM-B control (Johnson Controls) problems
- 2 red flashes
- 3 red flashes
- 4 amber flashes
- 4 red flashes
- 5 red flashes
- 6 red flashes
- 7 red flashes
- 8 red flashes
- 9 red flashes
- Rapid amber flash
- Rapid red flash
- Steady on red
See all Coleman 268897-UUM-B control (Johnson Controls) codes & guides →