Coleman Furnace 268897-UUM-B control (Johnson Controls) 7 red flashes

What this problem usually means

Flame could not be established. The no light condition occurred 3 times during the call for heat, and the furnace locks out for one hour.

Likely causes

  1. Low gas pressure
  2. Faulty gas valve
  3. Dirty or faulty flame sensor
  4. Faulty hot surface ignitor
  5. Burner problem

How to fix it — step by step

  1. The no light condition happened 3 times during the call before lockout, and the furnace restarts after one hour. Find the cause before it restarts.
  2. Turn the power off and close the gas shutoff, then confirm the shutoff is open and other gas appliances work.
  3. Remove the burner door and inspect the ignitor for cracks. On this control the warm up is 17 seconds on the first try and 27 seconds on retries.
  4. Restore power and watch a try. Ignitor glows, valve opens, flame should prove within 2 seconds of the valve opening per the manual sequence.
  5. If flame lights and drops, clean the flame sensor rod with fine steel wool. If there is no flame at all with a glowing ignitor, the gas valve or gas pressure is the fault, and that is pro work. → Shop the flame sensor at Amazon → Shop the gas valve at Amazon
  6. Verify the fix: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $150–$250

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Coleman Furnace 268897-UUM-B control (Johnson Controls) problems

See all Coleman 268897-UUM-B control (Johnson Controls) codes & guides →