Coleman Furnace 268897-UUM-B control (Johnson Controls) 8 red flashes

What this problem usually means

Flame was lost 5 times during the heating cycle. The furnace locks out for one hour and then restarts.

Likely causes

  1. Low gas pressure
  2. Dirty or faulty flame sensor
  3. Faulty gas valve

How to fix it — step by step

  1. Flame loss during the cycle points first at the sensor and the gas supply. The furnace locks out for one hour after 5 losses, then restarts.
  2. Turn the power off and clean the flame sensor rod with fine steel wool until bright.
  3. Check the vent and intake for partial blockage that disturbs the flame mid cycle.
  4. Restore power and watch a full cycle. The manual counts a flame lost for 2 seconds in the stabilization period as a recycle, so watch the first minute closely.
  5. If flame still drops with a clean sensor, call a pro to check gas pressure under load and the gas valve. Do not adjust gas pressure yourself.
  6. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $150–$250

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Coleman Furnace 268897-UUM-B control (Johnson Controls) problems

See all Coleman 268897-UUM-B control (Johnson Controls) codes & guides →