Coleman Furnace 268897-UUM-B control (Johnson Controls) 9 red flashes
What this problem usually means
Reversed line voltage polarity, or a grounding problem. Both heating and cooling operation are affected.
Likely causes
- Line voltage polarity reversed at the furnace or the branch circuit
- Furnace not grounded
- Flame probe shorted to the chassis
How to fix it — step by step
- Both heating and cooling are affected by this fault. Turn the power off at the breaker before opening the junction box.
- Check polarity at the furnace and at the branch circuit with a meter. Line to ground should read about 120 volts and neutral to ground near zero.
- Check the furnace ground connection and tighten the bond to the cabinet.
- Inspect the flame probe wire where it passes the burner housing. A probe shorted to the chassis sets this code too, per the manual.
- Correct the wiring or the short, restore power, and run a heat call. If line voltage work is not your trade, call an electrician or HVAC pro.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable taking it apart yourself, a repair shop is the next step.
Parts that commonly fix it
No specific replacement part is documented for this fault. If the checks above do not clear it, your furnace likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Coleman Furnace 268897-UUM-B control (Johnson Controls) problems
- Rapid amber flash
- Rapid red flash
- Steady on red
- 1 red flash
- 10 red flashes
- 11 red flashes
- 12 red flashes
- 2 red flashes
- 3 red flashes
- 4 amber flashes
- 4 red flashes
- 5 red flashes
See all Coleman 268897-UUM-B control (Johnson Controls) codes & guides →