Coleman Furnace 268897-UUM-B control (Johnson Controls) 6 red flashes
What this problem usually means
After the unit was operating, the pressure switch opened 4 times during the call for heat. The furnace locks out for one hour and then restarts.
Likely causes
- Vent or intake partially blocked so draft fades mid cycle
- Pressure switch hose loose or cracked
- Weak inducer motor
- Failing pressure switch
How to fix it — step by step
- The furnace locks out for one hour and then restarts on its own. Use the hour to find the cause instead of waiting it out.
- Turn the power off and check the vent and intake pipes and terminations for partial blockage.
- Inspect the pressure switch hose for cracks or a loose fit at either end, and clear the inducer port.
- Restore power and watch a full cycle. Draft that fades as the inducer heats up points to the inducer motor. → Shop the inducer motor at Amazon
- Test the switch during a run if you have a meter. A switch that drops out under steady draft has failed. Replace it with the correct setpoint part.
- Verify the fix: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the pressure switch.
Shop the pressure switch at Amazon
Also tied to this fault: inducer motor - Shop at Amazon
Parts that commonly fix it
- pressure switch$50–$205Shop at Amazon
- inducer motor$50–$215Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Coleman Furnace 268897-UUM-B control (Johnson Controls) problems
- 7 red flashes
- 8 red flashes
- 9 red flashes
- Rapid amber flash
- Rapid red flash
- Steady on red
- 1 red flash
- 10 red flashes
- 11 red flashes
- 12 red flashes
- 2 red flashes
- 3 red flashes
See all Coleman 268897-UUM-B control (Johnson Controls) codes & guides →