Coleman Furnace 268897-UUM-B control (Johnson Controls) 11 red flashes

What this problem usually means

A primary or auxiliary limit switch has stayed open for more than five minutes. With no airflow, the heat has nowhere to go.

Likely causes

  1. Failed blower motor
  2. Failed or loose blower wheel

How to fix it — step by step

  1. This is a hard lockout. Cycle power to the control to reset it, but only after the failure is corrected.
  2. Turn the power off and remove the blower door. Spin the blower wheel by hand. It should turn freely and sit tight on the motor shaft.
  3. A wheel that wobbles or slips has a loose set screw or a damaged hub. Tighten or replace the wheel.
  4. Test the blower motor. A motor that hums and never turns with a good capacitor has failed. → Shop the blower motor at Amazon
  5. The manual names a failed blower motor or blower wheel as the usual cause. Motor replacement is pro work for most owners.
  6. Verify the fix: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $95–$450Typical pro repair $150–$2,000

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Coleman Furnace 268897-UUM-B control (Johnson Controls) problems

See all Coleman 268897-UUM-B control (Johnson Controls) codes & guides →