Coleman Furnace 268897-UUM-B control (Johnson Controls) Rapid red flash

What this problem usually means

Twinning error, or incorrect 24 volt phasing. The control is reporting a wiring or phasing problem, most often on a twinned installation.

Likely causes

  1. Twinning wiring error on a twinned pair of furnaces
  2. Incorrect 24 volt phasing between twinned controls

How to fix it — step by step

  1. This code applies to twinned furnaces, two furnaces on one thermostat and duct system. On a single furnace install, note the code and call a pro, since it can mean the control is configured for twinning by mistake.
  2. Turn the power off to both furnaces before touching wiring.
  3. Compare the twinning wiring between the two controls against the wiring diagram. Correct crossed or loose low voltage wires.
  4. Confirm the 24 volt phasing matches on both controls, with the same transformer leg feeding the same terminal.
  5. Restore power to both units and call for heat. Both should start together. If the rapid flash returns, call a pro to verify the twinning setup.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

No specific replacement part is documented for this fault. If the checks above do not clear it, your furnace likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Coleman Furnace 268897-UUM-B control (Johnson Controls) problems

See all Coleman 268897-UUM-B control (Johnson Controls) codes & guides →