Slant/Fin Boiler Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 15 problems covered.
Not sure of the code? Tap along with it
If your Slant/Fin Boiler blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Finding your model number: it is on the rating plate on the boiler jacket, often behind the front panel.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
Prodigy 21 control (diagnostic LED patterns)
The Prodigy 21 control reports faults as patterns on its diagnostic LED - count the flashes (1 to 7), or note steady on / continuous flashing. The manual's troubleshooting sections give test values for each pattern, including flame current of at least 1 microamp, typically 5-10.
| Problem | What it means | Check first | |
|---|---|---|---|
| 1 flash | One flash of the Prodigy 21 diagnostic LED means the high limit has been open for one hour. The boiler… | High limit open for one hour | › |
| 2 flashes | Two flashes means no ignition: no flame signal after the trial for ignition. The manual's cause list runs… | No gas supply to the gas valve or burner | › |
| 3 flashes | Three flashes means a pressure switch problem. The control cannot prove correct airflow for combustion. The… | Pressure switch wiring fault | › |
| 4 flashes | Four flashes means hot surface ignitor failure. The manual's causes are the ignitor's electrical wiring, a… | Ignitor wiring fault | › |
| 5 flashes | Five flashes means blower RPM too low. The manual's causes are motor wiring faults (particularly the cable to… | Blower motor wiring fault, especially the RPM control cable | › |
| 6 flashes | Six flashes means the low water cutoff is open. The manual's test set is shared with the high limit checks: a… | Low water cutoff open | › |
| 7 flashes | Seven flashes means an improper flame signal: a flame signal was detected when the gas valve should be… | Flame signal detected with the gas valve supposed to be closed | › |
| Continuous flashing (diagnostic LED) | On the Prodigy 21 control, a continuously flashing red diagnostic LED means electronic control failure. The… | Electronic control failure | › |
| Steady on | A steady-on Prodigy 21 diagnostic LED means loss of flame signal: the flame signal was lost after a proper… | Flame signal lost after being established | › |
Victory VSPH (LED combination codes)
The Victory's integrated control combines its POWER, TSTAT/CIRC, PRES SWITCH and FLAME lights into flashing combinations - which lights flash together is the code. A lockout resets by switching power off for at least 45 seconds; the control also retries automatically after an hour (half an hour for flame failure).
| Problem | What it means | Check first | |
|---|---|---|---|
| FLAME LED flashing | A flashing FLAME LED by itself is a control lockout: the pilot flame was not established during the trial for… | Pilot flame not established during trial for ignition | › |
| POWER + FLAME LEDs flashing | Flashing POWER and FLAME LEDs together is a control lockout: flame was sensed without a call for heat. The… | Flame sensed without a call for heat | › |
| POWER + PRES SWITCH LEDs flashing | Flashing POWER and PRESS SWITCH LEDs together is a control lockout: the pressure switch contacts are closed… | Pressure switch contacts closed before the blower starts | › |
| POWER + TSTAT/CIRC LEDs flashing | Flashing POWER and TSTAT/CIRC LEDs together is a control lockout indicating 48 VAC on the thermostat circuit… | 48 VAC on the thermostat circuit | › |
| POWER LED flashing | On the Victory VSPH integrated boiler control, a flashing POWER LED by itself is a control lockout indicating… | 120 V power supply polarity reversed | › |
| PRES SWITCH LED flashing | A flashing PRES SWITCH LED by itself means the pressure switch opened during the boiler run period. The… | Pressure switch opened during the run | › |
Common questions
How do I read a Slant/Fin Prodigy fault code?
Count the diagnostic LED's flashes. The Prodigy 21 manual's Boiler Failure Codes list runs from 1 flash through 7 flashes, plus steady on and continuous flashing - each pattern is a different fault with its own causes and checks.
Once you know the part you need, browse Slant/Fin Boiler replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.