Slant/Fin Boiler Common Problems

Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 15 problems covered.

Not sure of the code? Tap along with it

If your Slant/Fin Boiler blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.

Your taps: -

Finding your model number: it is on the rating plate on the boiler jacket, often behind the front panel.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

Prodigy 21 control (diagnostic LED patterns)

The Prodigy 21 control reports faults as patterns on its diagnostic LED - count the flashes (1 to 7), or note steady on / continuous flashing. The manual's troubleshooting sections give test values for each pattern, including flame current of at least 1 microamp, typically 5-10.

ProblemWhat it meansCheck first
1 flashOne flash of the Prodigy 21 diagnostic LED means the high limit has been open for one hour. The boiler…High limit open for one hour›
2 flashesTwo flashes means no ignition: no flame signal after the trial for ignition. The manual's cause list runs…No gas supply to the gas valve or burner›
3 flashesThree flashes means a pressure switch problem. The control cannot prove correct airflow for combustion. The…Pressure switch wiring fault›
4 flashesFour flashes means hot surface ignitor failure. The manual's causes are the ignitor's electrical wiring, a…Ignitor wiring fault›
5 flashesFive flashes means blower RPM too low. The manual's causes are motor wiring faults (particularly the cable to…Blower motor wiring fault, especially the RPM control cable›
6 flashesSix flashes means the low water cutoff is open. The manual's test set is shared with the high limit checks: a…Low water cutoff open›
7 flashesSeven flashes means an improper flame signal: a flame signal was detected when the gas valve should be…Flame signal detected with the gas valve supposed to be closed›
Continuous flashing (diagnostic LED)On the Prodigy 21 control, a continuously flashing red diagnostic LED means electronic control failure. The…Electronic control failure›
Steady onA steady-on Prodigy 21 diagnostic LED means loss of flame signal: the flame signal was lost after a proper…Flame signal lost after being established›

Victory VSPH (LED combination codes)

The Victory's integrated control combines its POWER, TSTAT/CIRC, PRES SWITCH and FLAME lights into flashing combinations - which lights flash together is the code. A lockout resets by switching power off for at least 45 seconds; the control also retries automatically after an hour (half an hour for flame failure).

ProblemWhat it meansCheck first
FLAME LED flashingA flashing FLAME LED by itself is a control lockout: the pilot flame was not established during the trial for…Pilot flame not established during trial for ignition›
POWER + FLAME LEDs flashingFlashing POWER and FLAME LEDs together is a control lockout: flame was sensed without a call for heat. The…Flame sensed without a call for heat›
POWER + PRES SWITCH LEDs flashingFlashing POWER and PRESS SWITCH LEDs together is a control lockout: the pressure switch contacts are closed…Pressure switch contacts closed before the blower starts›
POWER + TSTAT/CIRC LEDs flashingFlashing POWER and TSTAT/CIRC LEDs together is a control lockout indicating 48 VAC on the thermostat circuit…48 VAC on the thermostat circuit›
POWER LED flashingOn the Victory VSPH integrated boiler control, a flashing POWER LED by itself is a control lockout indicating…120 V power supply polarity reversed›
PRES SWITCH LED flashingA flashing PRES SWITCH LED by itself means the pressure switch opened during the boiler run period. The…Pressure switch opened during the run›

Common questions

How do I read a Slant/Fin Prodigy fault code?
Count the diagnostic LED's flashes. The Prodigy 21 manual's Boiler Failure Codes list runs from 1 flash through 7 flashes, plus steady on and continuous flashing - each pattern is a different fault with its own causes and checks.

Looking for a part?

Once you know the part you need, browse Slant/Fin Boiler replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.